Unfortunately, I have no experience with either the HTM07KW motor or the EZ-A72400 controller so I don't know what sort of regen current output you might expect to see, or whether continuous regen operation would cause any problems.
The EZ-A72400 has a rated motor power of 3-6kW, but the HTM07KW is rated at 7kW with a peak of 18kW therefore the EZ- A72500 rated for a 4-7kW motor (or even the EZ-A72800 rated for 7-12kw motor) might be a better choice of controller if more power is likely to be required occasionally.
As the HTM07KW motor is rated for 92A @ 72V
(6.624kW @ 1,950rpm) I'm guessing that it might produce a regen output of ~78A @ 84V maximum charging voltage
(6.552kW @ 2,275rpm) if the regen efficiency is somewhere near the motor's power output efficiency.
I also noticed that the 7 and 11kW motors are both described as having "Natural cooling" yet they both appear to have liquid cooling pipe connections.